Locking Maxillofacial Reconstruction Straight Plate (Thread Guide)
Composition: medical-grade titanium
Measurement of thickness: 2.4 mm
Product specification
Item No. |
Specification |
|
10.01.06.08011100 |
8 holes |
69mm |
10.01.06.10011100 |
10 holes |
86mm |
10.01.06.12011100 |
12 holes |
103mm |
10.01.06.14011100 |
14 holes |
120mm |
10.01.06.16011100 |
16 holes |
137mm |
10.01.06.18011100 |
18 holes |
154mm |
10.01.06.20011100 |
20 holes |
171mm |
Mandibular trauma symptoms include comminuted fractures, unstable fractures, infected nonunions, and bone defects.
• Mandibular reconstruction: Used for dissociative bone blocks or bone grafts for first or second reconstruction (if there is no bone graft in the first operation, the reconstruction plate can only support the reconstruction for a limited amount of time and a second bone graft operation is required to support the reconstruction plate).
Advantages & Features:
• The reconstruction plate's pitch-row is a specially designed feature that improves fatigue strength and the phenomena of stress concentration in a particular place during operation.
• A locking reconstruction plate can be used to achieve an optimal fixation even in cases of osteoporotic mandibles, as it functions as an integrated external fixation support.
Equivalent screw: φ2.4mm non-heading locking screw
The matching tool is a medical drill bit (φ1.7*57*82 mm) and a cross head screw driver (SW0.5*2.8*95 mm) with a straight quick coupling handle and several functions.
1. The position of the fracture, the magnitude and direction of the external force, the direction and inclination of the fracture line, the presence of teeth in the fracture segment, and the pulling action of the associated muscle are the parameters that determine the displacement of the fracture segment following a mandibular fracture.Different portions of the fracture and muscle straining in different directions frequently cause variable displacement of the fracture segment.
2. Diffusive disorders
3. Atypical movement of the fractured area
4. The lower lip is numb
5. Limited opening of the mouth
6. Gum rip
When using the titanium mandibular plate for internal fixation, positive outcomes were seen. The splint has the following advantages: the dental force could be fully supported by the thin, narrow titanium plate. Prefabricated titanium plates have two adaptability options: they can be bent to match the mandible's radian or tilted to match its angle.In order to directly bear and convey the dental force, the titanium plate is fixed with the fractured ends of both sides of the bone. This prevents the graft bone flap from bearing the dental force and is highly advantageous for bone healing.Firm retention, no need for external fixation, the ability to cure wounds while eating normally, no need to wait for bone callus to form, all contribute to an early functional recovery and a shorter hospital stay for patients. The combination of repair type titanium splint internal fixation and vascular graft of iliac bone flap is very beneficial to the reconstruction of the patient's mandibular bone and the recovery of the appearance, chewing, swallowing, breathing, and speech, among other important functions, in patients with large mandibular defects resulting from tumor resection and other reasons.
Generally speaking, the mandibular locking plate must be symmetrically built to accommodate the divergent demands of the maxillofacial regions on the left and right sides. Concurrently, the mandibular locking plate's shaping and locking screws are positioned at an angle on the bone plate, making it difficult to surgically cure a fracture or reduce one. The maxillofacial universal lock plate, which includes mounting holes, is described in the maxillofacial universal central locking plate bending. The maxillofacial universal described an angle of 120 degrees between the locking plate on both sides. The maxillofacial universal lock plate side with multiple mounting holes is described in that document. The other side of the maxillofacial universal lock plate with multiple mounting holes is also described there. The installation holes are described in that document along with the symmetric distribution of the mounting holes and the cooperation of the installation hole axis. The installation hole's inner side has a trapezoidal installation hole, with a trapezoidal installation hole section. Similarly, the matching installation hole's inner side has a matching trapezoidal installation hole section, and both the matching and the trapezoidal installation holes are distributed symmetrically.The Maxillofacial Universal Locking Plate is a versatile device that may be used on both sides. Its installation hole allows for nail placement at an angle of thirty degrees, eliminating the necessity for left and right symmetrical product design.Maxillofacial universal locking plates may meet a range of needs. They can achieve one-step locking, angle locking up to 30 degrees, and compatibility with both left and right sides.