Anatomical Orbital Floor Plate
Anatomical Orbital Floor Plate

Anatomical Orbital Floor Plate

Utilization
Specifically designed to restore the normal shape and function of the eye after orbital injuries and repair.

Composition: medical-grade titanium

Product specification

Thickness

Item No.

Specification

0.4mm

12.09.0411.303041

left

30*30mm

12.09.0411.303042

right

0.5mm

12.09.0411.303001

left

12.09.0411.303002

right

 

Thickness

Item No.

Specification

0.4mm

12.09.0411.343643

left

34*36mm

12.09.0411.343644

right

0.5mm

12.09.0411.343603

left

12.09.0411.343604

right

Features & Benefits:

detail
• Efficiently avoid the optic hole and other significant structures in accordance with the anatomy of the orbital floor and orbital wall structure design.
• Anatomy and lobulated design, which, to the greatest extent feasible, lessen the shaping burden and successfully restore the continuity of the orbital cavity's bone, saving time during surgery and minimizing surgical trauma and postoperative issues.
• Because the bottom orbital wall is as thin as paper, the titanium mesh in the orbital floor's back retains its hard area. aid in improving eye subsidence and diplopia, resetting the imprisoned eyeball tissue and fat, and restoring the volume of the orbital cavity and eye motions.

Cross head screwdriver: SW0.5*2.8*75/95mm straight quick coupling handle is the matching instrument.
These plates are designed to be used in selective craniomaxillofacial trauma cases. They are made up of implants that closely resemble the topographical architecture of the human orbital floor and medial wall. Formalized three-dimensional form: made with little bending or cutting required, which shortens the time needed to shape the plate.
Plate edges with contours: These allow for a smoother plate insertion through skin incision and less interference between the surrounding soft tissue and the plate. 

Segmented design: to maintain rounded plate boundaries with few sharp edges and to adjust plate size to suit orbital terrain.

Rigid zone: Helps keep the globe in the proper position by restoring the curvature of the posterior orbital floor. all-inclusive orbital floor rebuilding and repair services.

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Quality You Can Rely On

We partner with trusted manufacturers to provide medical supplies that uphold the highest standards of safety and efficiency, supporting outstanding patient care.

Features

We supply products that meet international quality standards, ensuring safety and reliability. With advanced technology, they support precision in diagnosis and treatment.

Benefits

Our high-quality supplies ensure accurate patient care, with durable designs built to withstand the demands of clinical and hospital environments.

You may also like