Products
5.0 Straight Locking Plate 5.0 Straight Locking Plate
To add this product to your wish list you must Sign In or Create an account
Features of the 5.0 Straight Locking Plate
1. Medical titanium and cutting-edge processing technology;
2. Low profile design lessens discomfort to delicate tissues;
3. The anodised surface;
4. Designing anatomical shapes;
5. Combi-hole offers the option of both cortical and locking screws;
Indication: Pediatric femur fractures, tibia fractures, and humerus fractures can all benefit from orthopedic implants with 5.0 series straight thin locking plates.
paired with a medical tool set from the 5.0 series; used for Φ5.0 locking screws and Φ4.5 cortical screws.
Trauma plate for the narrow type 5.0 Series straight locking plate specification
Order code |
Specification |
|
10.14.08.08011300 |
8 Holes |
145mm |
10.14.08.09011300 |
9 Holes |
161mm |
10.14.08.10011300 |
10 Holes |
177mm |
*10.14.08.12011300 |
12 Holes |
209mm |
Straight Locking Plate, 5.0 Series
Broad Type Features:
1. Utilizing cutting-edge processing techniques and medical titanium;
2. A low-profile design that lessens soft tissue irritation;
3. The anodised surface;
4. Designing anatomical shapes;
5. Combi-hole offers the option of both cortical and locking screws;
Indication: Femur and tibia fractures can be treated using a trauma plate of the 5.0 series straight broad locking plate.
paired with a medical tool set from the 5.0 series; used for Φ5.0 locking screws and Φ4.5 cortical screws.
Broad Type Straight Locking Plate Specification for Orthopedic Implants in the 5.0 Series
Features of the 5.0 Straight Locking Plate
1. Medical titanium and cutting-edge processing technology;
2. Low profile design lessens discomfort to delicate tissues;
3. The anodised surface;
4. Designing anatomical shapes;
5. Combi-hole offers the option of both cortical and locking screws;
Indication: Pediatric femur fractures, tibia fractures, and humerus fractures can all benefit from orthopedic implants with 5.0 series straight thin locking plates.
paired with a medical tool set from the 5.0 series; used for Φ5.0 locking screws and Φ4.5 cortical screws.
Trauma plate for the narrow type 5.0 Series straight locking plate specification
Order code |
Specification |
|
10.14.08.08011300 |
8 Holes |
145mm |
10.14.08.09011300 |
9 Holes |
161mm |
10.14.08.10011300 |
10 Holes |
177mm |
*10.14.08.12011300 |
12 Holes |
209mm |
Straight Locking Plate, 5.0 Series
Broad Type Features:
1. Utilizing cutting-edge processing techniques and medical titanium;
2. A low-profile design that lessens soft tissue irritation;
3. The anodised surface;
4. Designing anatomical shapes;
5. Combi-hole offers the option of both cortical and locking screws;
Indication: Femur and tibia fractures can be treated using a trauma plate of the 5.0 series straight broad locking plate.
paired with a medical tool set from the 5.0 series; used for Φ5.0 locking screws and Φ4.5 cortical screws.
Broad Type Straight Locking Plate Specification for Orthopedic Implants in the 5.0 Series