Distal Fibular Locking Plate
Distal Fibular Locking Plate
Distal Fibular Locking Plate

Distal Fibular Locking Plate

Type I Anterior Lateral Distal Fibular Locking Plate
Anatomical features include the distal anterior lateral fibular trauma locking plate's form and profile along the fibular shaft.

Qualities:  
1. Produced using titanium and cutting-edge processing techniques; 

2. Low profile design lessens discomfort to sensitive tissues; 

3. Surface anodizing;

4. Anatomical form design; 

5. Combi-hole allows for the selection of both cortical and locking screws;

Distal-Anterior-Lateral-Fibular-Locking-Plate-I-Type

Indication: Osteotomies, nonunions, and fractures of the metaphyseal and diaphyseal region of the distal fibular, particularly in osteopenic bone, are suggested for the distal anterior lateral fibular locking implant plate.

Used for Φ3.0 locking screw, Φ3.0 cortex screw, matched with 3.0 series surgical instrument set.

Order code

Specification

10.14.35.04101000

Left 4 Holes

85mm

10.14.35.04201000

Right 4 Holes

85mm

*10.14.35.05101000

Left 5 Holes

98mm

10.14.35.05201000

Right 5 Holes

98mm

10.14.35.06101000

Left 6 Holes

111mm

10.14.35.06201000

Right 6 Holes

111mm

10.14.35.07101000

Left 7 Holes

124mm

10.14.35.07201000

Right 7 Holes

124mm

10.14.35.08101000

Left 8 Holes

137mm

10.14.35.08201000

Right 8 Holes

137mm

 

Fibular locking plate-II type located distal posterior laterally
Anatomical distal and longitudinal fibular shaft shape and profile characterize the distal posterior lateral fibular locking plate implant.

Qualities:  
1. produced using titanium and cutting-edge processing techniques; 

2. low profile design lessens discomfort to soft tissues;

3. surface anodizing;

4. anatomical shape design;

5. Combi-hole offers the option of both cortical and locking screws; 

Distal-Posterior-Lateral-Fibular-Locking-Plate-II-Type

Diaphyseal and metaphyseal fractures, osteotomies, and nonunions in the distal fibular region are appropriate for the distal posterior lateral fibular orthopedic locking plate, especially in cases of osteopenic bone.
Used with a 3.0 sries medical instrument kit, Φ3.0 cortical screw, and Φ3.0 locking screw.

Order code

Specification

10.14.35.04102000

Left 4 Holes

83mm

10.14.35.04202000

Right 4 Holes

83mm

*10.14.35.05102000

Left 5 Holes

95mm

10.14.35.05202000

Right 5 Holes

95mm

10.14.35.06102000

Left 6 Holes

107mm

10.14.35.06202000

Right 6 Holes

107mm

10.14.35.08102000

Left 8 Holes

131mm

10.14.35.08202000

Right 8 Holes

131mm

 

Type III Distal Lateral Fibular Locking Plate
Anatomical features include the distal lateral fibular trauma locking plate's form and profile along the fibular shaft.

Qualities:  
1. Surface anodized; 

2. Designed with anatomical shape;

3. Made of titanium and cutting-edge processing technology;

4. A low profile shape lessens discomfort to soft tissues; 

5. Combi-hole offers the option of both cortical and locking screws; 

Distal-Lateral-Fibular-Locking-Plate-III-Type

Distal lateral fibular locking plates are recommended for fractures, osteotomies, and nonunions of the distal fibular's metaphyseal and diaphyseal regions, particularly in cases with osteopenic bone.
matched with the orthopedic instrument set from the 3.0 series; used for Φ3.0 locking screw and Φ3.0 cortical screw.

Order code

Specification

10.14.35.04003000

4 Holes

79mm

10.14.35.05003000

5 Holes

91mm

10.14.35.06003000

6 Holes

103mm

10.14.35.08003000

8 Holes

127mm

 

This site is protected by hCaptcha and the hCaptcha Privacy Policy and Terms of Service apply.

Quality You Can Rely On

We partner with trusted manufacturers to provide medical supplies that uphold the highest standards of safety and efficiency, supporting outstanding patient care.

Features

We supply products that meet international quality standards, ensuring safety and reliability. With advanced technology, they support precision in diagnosis and treatment.

Benefits

Our high-quality supplies ensure accurate patient care, with durable designs built to withstand the demands of clinical and hospital environments.

You may also like